RTCA SC-186 Working
Group #5
UAT MOPS Development
Files to Support
Test Procedures
Files
to Support UAT MOPS (RTCA/DO-282A) Test Procedures
Some
Test Procedures in RTCA/DO-282A require set up of Vector Signal Analyzers,
Signal Generators and/or the insertion of UAT Messages with exact
strings of data input engineered to verify that a particular UAT
System is compliant with the requirement stated in the respective
requirements section of the document.
In an effort to ensure that the input of data, or the set
up of a particular piece of test hardware is consistent across multiple
vendors of UAT Equipment, we are providing the following set of
files for UAT Equipment vendors to download and use in their testing
efforts.
|
File
Name |
DO-282A
Section |
Description |
|
UAT-DMD.STA |
2.4.2.1
2.4.2.3
2.4.2.4
|
A
state file used to configure the Agilent HP89441A Vector Signal
Analyzer into the “Digital Demodulation” mode. |
|
XT_ENC_BASIC.DOC |
2.4.3.1.3.1 |
A
file that contains Basic ADS-B UAT Messages and its associated
FEC Parity sequence as tabulated in DO-282A, Table 2-73.
The data is written in HEX format. |
|
XT_ENC_LONG.DOC |
2.4.3.1.3.1 |
A
file that contains Long ADS-B UAT Messages and its associated
FEC Parity sequence as tabulated in DO-282A, Table 2-74.
The data is written in HEX format. |
|
UAT-VECT.STA |
2.4.8.2.3
2.4.8.2.4
|
A
state file used to configure the Agilent HP89441A Vector Signal
Analyzer into the “Vector” mode. |
|
RX_DEC_BURST.DOC |
2.4.8.3.1.1
|
Tables
that contain erroneous ADS-B UAT Messages (all 384 bits long),
status, decoded Message Type, RS decoded ADS-B UAT Message Payload
sequence as tabulated in DO-282A, Table 2-104.
The data is written in HEX format. |
|
RX_DEC_BRAND.DOC |
2.4.8.3.1.1
|
Tables
that contain erroneous ADS-B UAT Messages (all 384 bits long),
status, decoded Message Type, RS decoded ADS-B UAT Message Payload
sequence as tabulated in DO-282A, Table 2-105.
The data is written in HEX format. |
|
RX_DEC_GROUND.DOC |
2.4.8.3.1.2
|
Tables
that contain de-interleaved six consecutive erroneous RS blocks
(736 bits long) for each of nine Ground Uplink Messages, status,
decoded RS block and Ground Uplink Message status, as tabulated
in DO-282A, Table 2-106 through Table 2-114.
The data is written in HEX format. |